(Created page with "By default glance notifications are simply discarded (via the so-called '''noop''' notification strategy). So the first step is to ensure that these notifications are routed v...") |
No edit summary |
||
Line 15: | Line 15: | ||
| image.upload | delta | c0c77c78-90ad-40d1-b552-d98eeb8840ef | | 14b14be2016d4ce8b2d8a13578e279b0 | | | image.upload | delta | c0c77c78-90ad-40d1-b552-d98eeb8840ef | | 14b14be2016d4ce8b2d8a13578e279b0 | | ||
+--------------+-------+--------------------------------------+---------+----------------------------------+ | +--------------+-------+--------------------------------------+---------+----------------------------------+ | ||
Choose an image and download it: | |||
IMAGE_ID=$(glance image-list | awk '/ t / {print $2}' | head -1) | |||
glance image-download $IMAGE_ID | wc -c | |||
Check that the corresponding image.download meter reflects the volume of image data downloaded: | |||
ceilometer sample-list -c image.download -r $IMAGE_ID | |||
Then download again and note the availability of an additional sample point: | |||
glance image-download $IMAGE_ID > /dev/null | |||
ceilometer sample-list -c image.download -r $IMAGE_ID |
Revision as of 14:39, 2 April 2013
By default glance notifications are simply discarded (via the so-called noop notification strategy). So the first step is to ensure that these notifications are routed via the qpid AMQP provider instead:
sudo openstack-config --set /etc/glance/glance-api.conf DEFAULT notifier_strategy qpid sudo service openstack-glance-api restart
Then use the ceilometer CLI to display the image.* meters:
ceilometer meter-list +--------------+-------+--------------------------------------+---------+----------------------------------+ | Name | Type | Resource ID | User ID | Project ID | +--------------+-------+--------------------------------------+---------+----------------------------------+ | image | gauge | c0c77c78-90ad-40d1-b552-d98eeb8840ef | | 14b14be2016d4ce8b2d8a13578e279b0 | | image.size | gauge | c0c77c78-90ad-40d1-b552-d98eeb8840ef | | 14b14be2016d4ce8b2d8a13578e279b0 | | image.update | delta | c0c77c78-90ad-40d1-b552-d98eeb8840ef | | 14b14be2016d4ce8b2d8a13578e279b0 | | image.upload | delta | c0c77c78-90ad-40d1-b552-d98eeb8840ef | | 14b14be2016d4ce8b2d8a13578e279b0 | +--------------+-------+--------------------------------------+---------+----------------------------------+
Choose an image and download it:
IMAGE_ID=$(glance image-list | awk '/ t / {print $2}' | head -1) glance image-download $IMAGE_ID | wc -c
Check that the corresponding image.download meter reflects the volume of image data downloaded:
ceilometer sample-list -c image.download -r $IMAGE_ID
Then download again and note the availability of an additional sample point:
glance image-download $IMAGE_ID > /dev/null ceilometer sample-list -c image.download -r $IMAGE_ID